01. Wastewater Treatment Is a Process-Control Challenge
Wastewater treatment involves multiple interdependent physical, chemical, and biological processes.
Operational performance can depend on sedimentation, sludge conditioning, dewatering, chemical consumption, equipment condition, deposit formation, maintenance requirements, and applicable discharge criteria.
A meaningful MundiMag™ evaluation should therefore be based on process measurements relevant to the specific facility rather than on the presence of magnetic conditioning equipment alone.
Measure the wastewater-treatment process, not simply the device.
02. Where MundiMag™ Can Be Evaluated
Potential evaluation points include:
Sludge conditioning
Flocculant preparation
Dewatering presses
Wastewater piping
Aerobic sludge digestion
Sedimentation
Struvite and mineral-deposit control
Selected process-water streams
These are separate application points. Evaluate their suitability, field configuration, and measurement criteria individually. One Magnetizer® installation should not be understood as performing all of these functions simultaneously.
Magnetic Water Conditioning: What It Is — And What It Isn’t →
03. What Wastewater Plants Should Measure
Measurements should reflect the treatment objective and the facility’s operating conditions. Relevant indicators can include:
Flocculant consumption per unit of dry matter
Dewatered-sludge condition and moisture
Sedimentation behavior
Capillary suction time where used by the facility
COD and phosphorus where applicable
Struvite and other deposit formation
Press-cleaning requirements
Equipment maintenance
Downtime
Applicable process and discharge criteria
Use comparable before-and-after measurements wherever possible. Agree on the chosen indicators and measurement method for the specific process.
04. Documented Project Experience: Braniewo, Poland
The Braniewo project evaluated permanent monopolar magnetic-field applications in sludge treatment, sludge conditioning, and dewatering operations.
The Braniewo project report records flocculant consumption changing from 3.4 to 2.2 kg/t dry matter, an approximate 35% reduction. It also reports dewatered-sludge moisture in the 76–84% range, depending on sludge composition, and six months of continued press-belt operation for belts previously scheduled for replacement.
These are project-specific observations, not universal performance guarantees. The supplied image set did not include a photograph of the Braniewo facility.
05. Braniewo Project Scorecard
The comparison below presents the reported flocculant figures alongside the other selected Braniewo observations.
BRANIEWO PROJECT SCORECARD
Reported outcomes from the Braniewo wastewater-treatment project
FLOCCULANT CONSUMPTION · kg/t DRY MATTER
Before · 3.4
After · 2.2
FLOCCULANT USE
3.4 → 2.2
kg/t dry matter
REPORTED REDUCTION
≈35%
Reported reduction in flocculant consumption.
DEWATERED SLUDGE MOISTURE
76–84%
Reported range depending on sludge composition.
PRESS-BELT OPERATION
6 months
Continued operation reported for belts previously scheduled for replacement.
Past application-specific results from the Braniewo project. Performance at another facility depends on wastewater composition, process design, field configuration, application point, hydraulic conditions, treatment chemistry, biological conditions, and measurement methodology.
06. Sludge Conditioning and Flocculant Use
At Braniewo, the project report records flocculant use changing from 3.4 to 2.2 kg/t dry matter, reported as an approximate 35% reduction.
Reduced chemical consumption may affect operating costs and chemical handling. The actual economic value must be calculated based on the facility’s throughput and treatment program; this article does not estimate monetary savings.
07. Dewatering, Press Operation and Maintenance
The Braniewo project material describes deposits reducing openings in the press belt, deposit removal, press-belt condition, and sludge dewatering.
It also reports continued operation for six months of belts previously scheduled for replacement. This is a project-specific operating observation, not a forecast for another facility.
Industrial Scale Control & Descaling with MundiMag™ →
08. COD, Phosphorus and Sedimentation
The Braniewo report documented changes in sedimentation behavior, COD, and phosphorus under specific tested magnetic-field configurations.
Different field orientations produced materially different process responses. These findings describe the tested Braniewo configurations; they do not establish that MundiMag™ universally reduces COD or phosphorus, and they should not be generalized to another wastewater plant.
09. Struvite Control: Braniewo and Psyttalia
The Braniewo engineering report identified struvite deposition in piping as an application for magnetic conditioning.
RELATED MUNDI EXPERIENCE: PSYTTALIA
Project documentation for Psyttalia records a 30 cm wastewater pipe with struvite accumulation and mechanical cleaning every 3–4 months before Magnetizer® installation. The two photographs below show the documented before-and-after condition of the pipe.

BEFORE
Struvite accumulation in a 30 cm wastewater pipe. Project documentation records mechanical cleaning every 3–4 months before Magnetizer® installation.

AFTER
The same pipe after six months with Magnetizer®. Project documentation reports removal of the existing struvite deposit and a subsequent 12-month operating period without struvite blockage.
Project-specific observations. Struvite formation depends on wastewater chemistry, process conditions, and facility configuration.
10. Large-Scale Wastewater Experience: Psyttalia
Mundi’s wastewater-treatment experience includes work on the large-scale Psyttalia biological wastewater-treatment facility in Greece. No treatment capacity, ranking, population-served figure, or current plant-performance claim is made here.

11. Magnetic Fields in Wastewater Treatment
Magnetic-field applications have been examined in wastewater-treatment and sludge-management research. This literature provides broader technical context for the subject; it does not prove every MundiMag™ claim or predict results at a particular site.
Theory of Operation → · Tests & Evaluations →
12. Why Application Point and Field Configuration Matter
The Braniewo work demonstrates why magnetic treatment cannot be treated as a generic one-position application. Reported positive- and negative-field configurations produced materially different process responses.
Installation point, field orientation, hydraulic conditions, sludge characteristics, chemistry, biological processes, and treatment objectives therefore need to be evaluated individually.
13. Facilities and Applications
Potential settings for a project-specific review can include:
Municipal wastewater plants
Industrial wastewater-treatment facilities
Food and beverage processing plants
Dairy plants
Manufacturing facilities
Airports with applicable wastewater infrastructure
Hospitals and large campuses with applicable treatment systems
Other large facilities using wastewater pretreatment or sludge processing
The list identifies possible contexts for review; it does not mean every facility is automatically suitable.
14. Project-Specific Engineering and Proprietary Know-How
The principles of process measurement and wastewater-treatment evaluation can be discussed publicly. Detailed MundiMag™ system selection, field orientation, installation location, configuration, verification, and commissioning form part of project-specific engineering.
Following contractual authorization, Mundi provides the client’s technical personnel with the applicable engineering and measurement documentation. Private engineering resources are not linked publicly.
15. Evaluate Your Wastewater Application
If flocculant consumption, sludge dewatering, struvite deposition, sedimentation, press maintenance, or related wastewater-treatment conditions represent significant operating issues, Mundimex can review the available process information to determine whether a controlled MundiMag™ pilot installation is appropriate.
A preliminary review can begin with:
Wastewater and process type
Existing treatment stages
Sludge characteristics where available
Flocculant use
Dewatering method
Struvite and deposit conditions
Relevant process measurements
Maintenance history
Photographs of affected equipment
Facility objectives
Learn More About Industrial Water Conditioning
If wastewater treatment, sludge dewatering, flocculant use, or struvite deposition is an operating concern, Mundimex can review the application. To learn more, explore our product pages for real-world applications in industry.
↑ GO TO TOP